ILT-U-1229
Vibration determination
DETERMINATION | METHOD |
| Sinusoidal vibrations: · Minimum frequency: 5 Hz · Maximum frequency: 2000 Hz · Lines: 4096 · Vibration amplitude: 0.5 g constant · Scanning speed: 1 octave/minute · Number of sweeps: 5 (UP direction) | IEC 60068-2-6:2007 |
| Random vibrations: Level 1 test · Minimum frequency: 10 Hz · Frequency f1: 20 Hz · Frequency f2: 1000 Hz · Maximum frequency: 2000 Hz · RMS value: 3.35 g · Shape ASD (flat between f1 and f2): 0.01 g2/Hz · Initial slope from 10 Hz: +6 dB/octave · Final slope between 1000 and 2000 Hz: -24 dB/octave · Lines: 3200 · Duration: 20 minutes | IEC 60068-2-64:2008/AMD1:2019 |
| Level 2 test · Minimum frequency: 10 Hz · Frequency f1: 20 Hz · Frequency f2: 1000 Hz · Maximum frequency: 2000 Hz · RMS value: 7,49 g · Shape ASD (flat between f1 and f2): 0.05 g2/Hz · Initial slope from 10 Hz: +6 dB/octave · Final slope between 1000 and 2000 Hz: -24 dB/octave · Lines: 3200 · Duration: 20 minutes | IEC 60068-2-64:2008/AMD1:2019 |
| Shock: Level 1 test · Waveform: semi-sinusoidal · Peak acceleration: 25 g · Pulse duration: 6 ms · Number of repetitions per verse: 10 · Duration: 2 minutes Level 2 test · Waveform: semi-sinusoidal · Peak acceleration: 15 g · Pulse duration: 11 ms · Number of repetitions per verse: 10 · Duration: 2 minutes Level 3 test · Waveform: semi-sinusoidal · Peak acceleration: 5 g · Pulse duration: 30 ms · Number of repetitions per verse: 10 · Duration: 2 minutes | IEC 60068-2-27:2008 |